Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Tumour Biol ; 46(s1): S191-S206, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38363625

RESUMO

BACKGROUND: Protein tumor markers are released in high amounts into the blood in advanced non-small cell lung cancer (NSCLC). OBJECTIVE: To investigate the relevance of serum tumor markers (STM) for prognosis, prediction and monitoring of therapy response in NSCLC patients receiving chemotherapy. METHODS: In a biomarker substudy of a prospective, multicentric clinical trial (CEPAC-TDM) on 261 advanced NSCLC patients, CYFRA 21-1, CEA, SCC, NSE, ProGRP, CA125, CA15-3 and HE4 were assessed in serial serum samples and correlated with radiological response after two cycles of chemotherapy and overall (OS) and progression-free survival (PFS). RESULTS: While pretherapeutic STM levels at staging did not discriminate between progressive and non-progressive patients, CYFRA 21-1, CA125, NSE and SCC at time of staging did, and yielded AUCs of 0.75, 0.70, 0.69 and 0.67 in ROC curves, respectively. High pretherapeutic CA15-3 and CA125 as well as high CYFRA 21-1, SCC, CA125 and CA15-3 levels at staging were prognostic for shorter PFS and OS -also when clinical variables were added to the models. CONCLUSIONS: STM at the time of first radiological staging and pretherapeutic CA15-3, CA125 are predictive for first-line treatment response and highly prognostic in patients with advanced NSCLC.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Antígenos de Neoplasias , Biomarcadores Tumorais , Antígeno Carcinoembrionário , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Queratina-19 , Neoplasias Pulmonares/patologia , Mucina-1 , Estudos Prospectivos
2.
Tumour Biol ; 46(s1): S355-S367, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38277316

RESUMO

BACKGROUND: Programmed cell death receptors and ligands in cancer tissue samples are established companion diagnostics for immune checkpoint inhibitor (ICI) therapies. OBJECTIVE: To investigate the relevance of soluble PD-1, PD-L1 and PD-L2 for estimating therapy response and prognosis in non-small cell lung cancer patients (NSCLC) undergoing platin-based combination chemotherapies. METHODS: In a biomarker substudy of a prospective, multicentric clinical trial (CEPAC-TDM) on advanced NSCLC patients, soluble PD-1, PD-L1 and PD-L2 were assessed in serial serum samples by highly sensitive enzyme-linked immunosorbent assays and correlated with radiological response after two cycles of chemotherapy and with overall survival (OS). RESULTS: Among 243 NSCLC patients, 185 achieved response (partial remission and stable disease) and 58 non-response (progression). The distribution of PD-1, PD-L1 and PD-L2 at baseline (C1), prior to staging (C3) and the relative changes (C3/C1) greatly overlapped between the patient groups with response and non-response, thus hindering the discrimination between the two groups. None of the PD markers had prognostic value regarding OS. CONCLUSIONS: Neither soluble PD-1, PD-L1 nor PD-L2 did provide clinical utility for predicting response to chemotherapy and prognosis. Studies on the relevance of PD markers in ICI therapies are warranted.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Humanos , Antígeno B7-H1/sangue , Antígeno B7-H1/metabolismo , Biomarcadores Tumorais/metabolismo , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/metabolismo , Prognóstico , Receptor de Morte Celular Programada 1/sangue , Estudos Prospectivos
3.
J Appl Lab Med ; 8(4): 726-741, 2023 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-37222567

RESUMO

BACKGROUND: Throughout the COVID-19 pandemic, veterinary diagnostic laboratories have tested diagnostic samples for SARS-CoV-2 both in animals and over 6 million human samples. An evaluation of the performance of those laboratories is needed using blinded test samples to ensure that laboratories report reliable data to the public. This interlaboratory comparison exercise (ILC3) builds on 2 prior exercises to assess whether veterinary diagnostic laboratories can detect Delta and Omicron variants spiked in canine nasal matrix or viral transport medium. METHODS: The ILC organizer was an independent laboratory that prepared inactivated Delta variant at levels of 25 to 1000 copies per 50 µL of nasal matrix for blinded analysis. Omicron variant at 1000 copies per 50 µL of transport medium was also included. Feline infectious peritonitis virus (FIPV) RNA was used as a confounder for specificity assessment. Fourteen test samples were prepared for each participant. Participants used their routine diagnostic procedures for RNA extraction and real-time reverse transcriptase-PCR. Results were analyzed according to International Organization for Standardization (ISO) 16140-2:2016. RESULTS: Overall, laboratories demonstrated 93% detection for Delta and 97% for Omicron at 1000 copies per 50 µL. Specificity was 97% for blank samples and 100% for blank samples with FIPV. No differences in Cycle Threshold (Ct) values were significant for samples with the same virus levels between N1 and N2 markers, nor between the 2 variants. CONCLUSIONS: The results indicated that all ILC3 participants were able to detect both Delta and Omicron variants. The canine nasal matrix did not significantly affect SARS-CoV-2 detection.


Assuntos
COVID-19 , SARS-CoV-2 , Gatos , Humanos , Animais , Cães , SARS-CoV-2/genética , COVID-19/diagnóstico , COVID-19/veterinária , Laboratórios , Pandemias , RNA , Teste para COVID-19
4.
J Vet Diagn Invest ; 34(5): 825-834, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35983593

RESUMO

The COVID-19 pandemic presents a continued public health challenge. Veterinary diagnostic laboratories in the United States use RT-rtPCR for animal testing, and many laboratories are certified for testing human samples; hence, ensuring that laboratories have sensitive and specific SARS-CoV2 testing methods is a critical component of the pandemic response. In 2020, the FDA Veterinary Laboratory Investigation and Response Network (Vet-LIRN) led an interlaboratory comparison (ILC1) to help laboratories evaluate their existing RT-rtPCR methods for detecting SARS-CoV2. All participating laboratories were able to detect the viral RNA spiked in buffer and PrimeStore molecular transport medium (MTM). With ILC2, Vet-LIRN extended ILC1 by evaluating analytical sensitivity and specificity of the methods used by participating laboratories to detect 3 SARS-CoV2 variants (B.1; B.1.1.7 [Alpha]; B.1.351 [Beta]) at various copy levels. We analyzed 57 sets of results from 45 laboratories qualitatively and quantitatively according to the principles of ISO 16140-2:2016. More than 95% of analysts detected the SARS-CoV2 RNA in MTM at ≥500 copies for all 3 variants. In addition, for nucleocapsid markers N1 and N2, 81% and 92% of the analysts detected ≤20 copies in the assays, respectively. The analytical specificity of the evaluated methods was >99%. Participating laboratories were able to assess their current method performance, identify possible limitations, and recognize method strengths as part of a continuous learning environment to support the critical need for the reliable diagnosis of COVID-19 in potentially infected animals and humans.


Assuntos
COVID-19 , SARS-CoV-2 , Animais , COVID-19/diagnóstico , COVID-19/veterinária , Teste para COVID-19 , Humanos , Imunidade Inata , Laboratórios , Linfócitos , Pandemias/veterinária , RNA Viral/análise , SARS-CoV-2/genética , Sensibilidade e Especificidade , Estados Unidos/epidemiologia
5.
Diagnostics (Basel) ; 12(6)2022 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-35741223

RESUMO

Background: Despite the significance of colonoscopy for early diagnosis of colorectal adenocarcinoma (CRC), population-wide screening remains challenging, mainly because of low acceptance rates. Herein, exosomal (exo-miR) and free circulating microRNA (c-miR) may be used as liquid biopsies in CRC to identify individuals at risk. Direct comparison of both compartments has shown inconclusive results, which is why we directly compared a panel of 10 microRNAs in this entity. Methods: Exo-miR and c-miR levels were measured using real-time quantitative PCR after isolation from serum specimens in a cohort of 69 patients. Furthermore, results were compared to established tumor markers CEA and CA 19-9. Results: Direct comparison of exo- and c-miR biopsy results showed significantly higher microRNA levels in the exosomal compartment (p < 0.001). Exo-Let7, exo-miR-16 and exo-miR-23 significantly differed between CRC and healthy controls (all p < 0.05), while no c-miR showed this potential. Sensitivity and specificity can be further enhanced using combinations of multiple exosomal miRNAs. Conclusions: Exosomal microRNA should be considered as a promising biomarker in CRC for future studies. Nonetheless, results may show interference with common comorbidities, which must be taken into account in future studies.

6.
Pharmaceuticals (Basel) ; 15(2)2022 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-35215332

RESUMO

Adverse effects of drug combinations and their underlying mechanisms are highly relevant for safety evaluation, but often not fully studied. Hydroxychloroquine (HCQ) and azithromycin (AZM) were used as a combination therapy in the treatment of COVID-19 patients at the beginning of the pandemic, leading to higher complication rates in comparison to respective monotherapies. Here, we used human-induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) to systematically investigate the effects of HCQ, AZM, and their combination on the structure and functionality of cardiomyocytes, and to better understand the underlying mechanisms. Our results demonstrate synergistic adverse effects of AZM and HCQ on electrophysiological and contractile function of iPSC-CMs. HCQ-induced prolongation of field potential duration (FPDc) was gradually increased during 7-day treatment period and was strongly enhanced by combination with AZM, although AZM alone slightly shortened FPDc in iPSC-CMs. Combined treatment with AZM and HCQ leads to higher cardiotoxicity, more severe structural disarrangement, more pronounced contractile dysfunctions, and more elevated conduction velocity, compared to respective monotreatments. Mechanistic insights underlying the synergistic effects of AZM and HCQ on iPSC-CM functionality are provided based on increased cellular accumulation of HCQ and AZM as well as increased Cx43- and Nav1.5-protein levels.

7.
Foods ; 12(1)2022 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-36613357

RESUMO

Food fraud, even when not in the news, is ubiquitous and demands the development of innovative strategies to combat it. A new non-targeted method (NTM) for distinguishing spelt and wheat is described, which aids in food fraud detection and authenticity testing. A highly resolved fingerprint in the form of spectra is obtained for several cultivars of spelt and wheat using liquid chromatography coupled high-resolution mass spectrometry (LC-HRMS). Convolutional neural network (CNN) models are built using a nested cross validation (NCV) approach by appropriately training them using a calibration set comprising duplicate measurements of eleven cultivars of wheat and spelt, each. The results reveal that the CNNs automatically learn patterns and representations to best discriminate tested samples into spelt or wheat. This is further investigated using an external validation set comprising artificially mixed spectra, samples for processed goods (spelt bread and flour), eleven untypical spelt, and six old wheat cultivars. These cultivars were not part of model building. We introduce a metric called the D score to quantitatively evaluate and compare the classification decisions. Our results demonstrate that NTMs based on NCV and CNNs trained using appropriately chosen spectral data can be reliable enough to be used on a wider range of cultivars and their mixes.

8.
Foods ; 10(11)2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34828926

RESUMO

Game meat products are particularly prone to be adulterated by replacing game meat with cheaper meat species. Recently, we have presented a real-time polymerase chain reaction (PCR) assay for the identification and quantification of roe deer in food. Quantification of the roe deer content in % (w/w) was achieved relatively by subjecting the DNA isolates to a reference real-time PCR assay in addition to the real-time PCR assay for roe deer. Aiming at harmonizing analytical methods for food authentication across EU Member States, the real-time PCR assay for roe deer has been tested in an interlaboratory ring trial including 14 laboratories from Austria, Germany, and Switzerland. Participating laboratories obtained aliquots of DNA isolates from a meat mixture containing 24.8% (w/w) roe deer in pork, roe deer meat, and 12 meat samples whose roe deer content was not disclosed. Performance characteristics included amplification efficiency, level of detection (LOD95%), repeatability, reproducibility, and accuracy of quantitative results. With a relative reproducibility standard deviation ranging from 13.35 to 25.08% (after outlier removal) and recoveries ranging from 84.4 to 114.3%, the real-time PCR assay was found to be applicable for the detection and quantification of roe deer in raw meat samples to detect food adulteration.

9.
J Vet Diagn Invest ; 33(6): 1039-1051, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34293974

RESUMO

The continued search for intermediate hosts and potential reservoirs for SARS-CoV2 makes it clear that animal surveillance is critical in outbreak response and prevention. Real-time RT-PCR assays for SARS-CoV2 detection can easily be adapted to different host species. U.S. veterinary diagnostic laboratories have used the CDC assays or other national reference laboratory methods to test animal samples. However, these methods have only been evaluated using internal validation protocols. To help the laboratories evaluate their SARS-CoV2 test methods, an interlaboratory comparison (ILC) was performed in collaboration with multiple organizations. Forty-four sets of 19 blind-coded RNA samples in Tris-EDTA (TE) buffer or PrimeStore transport medium were shipped to 42 laboratories. Results were analyzed according to the principles of the International Organization for Standardization (ISO) 16140-2:2016 standard. Qualitative assessment of PrimeStore samples revealed that, in approximately two-thirds of the laboratories, the limit of detection with a probability of 0.95 (LOD95) for detecting the RNA was ≤20 copies per PCR reaction, close to the theoretical LOD of 3 copies per reaction. This level of sensitivity is not expected in clinical samples because of additional factors, such as sample collection, transport, and extraction of RNA from the clinical matrix. Quantitative assessment of Ct values indicated that reproducibility standard deviations for testing the RNA with assays reported as N1 were slightly lower than those for N2, and they were higher for the RNA in PrimeStore medium than those in TE buffer. Analyst experience and the use of either a singleplex or multiplex PCR also affected the quantitative ILC test results.


Assuntos
COVID-19 , RNA Viral , Animais , COVID-19/veterinária , Laboratórios , RNA Viral/genética , Reprodutibilidade dos Testes , SARS-CoV-2 , Sensibilidade e Especificidade
10.
Oncotarget ; 9(32): 22523-22536, 2018 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-29854296

RESUMO

BACKGROUND: MicroRNAs biomarkers have shown value for diagnosis and prognosis of various cancers. Combination with established tumor markers has rarely been done. RESULTS: Breast cancer patients had significantly higher serum RNA loads (AUC 0.665), lower miR-34a (AUC 0.772), higher CEA and CA 15-3 levels (AUCs 0.717 and 0.721) than healthy controls. miR-34a correlated with tumor stage and hormone receptor status. There was no significant difference between groups for all other miRNAs. Combination of miR-34a with CEA or CA 15-3 led to improved AUCs of 0.844 and 0.800, respectively. Sensitivity of miR-34a and CA 15-3 reached 56.1% at 95% specificity. When compared with benign breast diseases, combination of miR-34a (AUC 0.719) and CEA (0.623) or CA 15-3 (0.619) resulted in improved performances (0.794 and 0.741). Sensitivity of miR-34a and CA 15-3 reached 53.7% at 95% specificity. CONCLUSION: While miR-34a provides valuable information for diagnosis and staging, combination with tumor markers CA15-3 or CEA improves the sensitivity for breast cancer detection. PATIENTS AND METHODS: The diagnostic relevance of the miR-21, miR-34a, miR-92a, miR-155, miR-222 and miR-let-7c was tested in sera of 103 individuals (55 breast cancer, 20 benign breast diseases, 28 healthy controls). MiRNAs were detected by quantitative rt-PCR after extraction and reverse transcription. Cel-miR-39 and miR-16 were used for normalization. Established tumor markers CEA, CA 15-3, CA 19-9 and CA 125 were measured by automatized immunoassays. Diagnostic performance was tested by areas under the curve (AUC) of receiver operating characteristic (ROC) curves and sensitivities at 90% and 95% specificity.

11.
Sci Total Environ ; 628-629: 748-765, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29454215

RESUMO

Effect-based methods including cell-based bioassays, reporter gene assays and whole-organism assays have been applied for decades in water quality monitoring and testing of enriched solid-phase extracts. There is no common EU-wide agreement on what level of bioassay response in water extracts is acceptable. At present, bioassay results are only benchmarked against each other but not against a consented measure of chemical water quality. The EU environmental quality standards (EQS) differentiate between acceptable and unacceptable surface water concentrations for individual chemicals but cannot capture the thousands of chemicals in water and their biological action as mixtures. We developed a method that reads across from existing EQS and includes additional mixture considerations with the goal that the derived effect-based trigger values (EBT) indicate acceptable risk for complex mixtures as they occur in surface water. Advantages and limitations of various approaches to read across from EQS are discussed and distilled to an algorithm that translates EQS into their corresponding bioanalytical equivalent concentrations (BEQ). The proposed EBT derivation method was applied to 48 in vitro bioassays with 32 of them having sufficient information to yield preliminary EBTs. To assess the practicability and robustness of the proposed approach, we compared the tentative EBTs with observed environmental effects. The proposed method only gives guidance on how to derive EBTs but does not propose final EBTs for implementation. The EBTs for some bioassays such as those for estrogenicity are already mature and could be implemented into regulation in the near future, while for others it will still take a few iterations until we can be confident of the power of the proposed EBTs to differentiate good from poor water quality with respect to chemical contamination.

12.
Sci Total Environ ; 621: 612-625, 2018 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-29195208

RESUMO

Endocrine-active substances can adversely impact the aquatic ecosystems. A special emphasis is laid, among others, on the effects of estrogens and estrogen mimicking compounds. Effect-based screening methods like in vitro bioassays are suitable tools to detect and quantify endocrine activities of known and unknown mixtures. This study describes the validation of the Arxula-Yeast Estrogen Screen (A-YES®) assay, an effect-based method for the detection of the estrogenic potential of water and waste water. This reporter gene assay, provided in ready to use format, is based on the activation of the human estrogen receptor alpha. The user-friendly A-YES® enables inexperienced operators to rapidly become competent with the assay. Fourteen laboratories from four countries with different training levels analyzed 17ß-estradiol equivalent concentrations (EEQ) in spiked and unspiked waste water effluent and surface water samples, in waste water influent and spiked salt water samples and in a mixture of three bisphenols. The limit of detection (LOD) for untreated samples was 1.8ng/L 17ß-estradiol (E2). Relative repeatability and reproducibility standard deviation for samples with EEQ above the LOD (mean EEQ values between 6.3 and 20.4ng/L) ranged from 7.5 to 21.4% and 16.6 to 28.0%, respectively. Precision results are comparable to other frequently used analytical methods for estrogens. The A-YES® has been demonstrated to be an accurate, precise and robust bioassay. The results have been included in the ISO draft standard. The assay was shown to be applicable for testing of typical waste water influent, effluent and saline water. Other studies have shown that the assay can be used with enriched samples, which lower the LOD to the pg/L range. The validation of the A-YES® and the development of a corresponding international standard constitute a step further towards harmonized and reliable bioassays for the effect-based analysis of estrogens and estrogen-like compounds in water samples.


Assuntos
Monitoramento Ambiental/métodos , Receptor alfa de Estrogênio/metabolismo , Estrogênios/análise , Saccharomycetales , Poluentes Químicos da Água/análise , Bioensaio , Disruptores Endócrinos , Estradiol/análise , Humanos , Limite de Detecção , Fenóis/análise , Reprodutibilidade dos Testes
13.
Sci Total Environ ; 605-606: 507-513, 2017 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-28672239

RESUMO

Arxula adeninivorans-based yeast cell assays for the detection of steroid hormones demonstrated their efficiency for the determination of total hormone activity in a variety of samples using a microtiter plate format. In this study, a preliminary chromatographic separation using thin-layer chromatography plates is introduced in order to allow a rapid identification of the compounds responsible for this hormonal activity. The yeast whole cell assay can then be performed on the plate, producing a detectable signal where a steroid hormone is present. Simultaneous detection of estrogens, progestogens and androgens on the same plate in the picogram range was achieved, while keeping the assay as simple and affordable as possible. The assay requires a single incubation of the thin-layer chromatography plate and the detection of reporter protein production can be performed by fluorescence scanning of the plate at different wavelengths. The chromatographic separation allows the separation of several estrogens, androgens and progestogens, thus making its application for 'real world' samples very useful. In this work, different water-based samples from environmental origins were used to demonstrate the capacity of this new bioassay. Trials showed that most samples, with the exception of complex samples such as wastewater influent, can be assayed.


Assuntos
Androgênios/análise , Bioensaio , Cromatografia em Camada Delgada , Estrogênios/análise , Poluentes Químicos da Água/análise , Saccharomycetales , Águas Residuárias/análise
14.
Tumour Biol ; 39(6): 1010428317711381, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28618926

RESUMO

Multiple factors contribute to the development and progression of breast cancer. Markers of tumor growth and invasion, cell death, immune activation, and angiogenesis can be assessed in parallel by a novel multiplex immunoassay panel. The diagnostic performance of a multiplex cancer biomarker magnetic bead panel comprising 24 tumor associated parameters was evaluated in sera of 154 women including 77 patients with breast cancer, 10 with precancerous lesions, 31 with benign breast diseases, and 36 healthy controls. Marker levels were log-transformed for variance stabilization. Significance testing was done using t-test or Wilcoxon rank-sum test with correction of p values for multiple testing. Furthermore, receiver operating characteristic analyses were performed. Serum levels of several biomarkers were significantly (p ≤ 0.001) higher in cancer patients than in healthy controls, particularly alpha-fetoprotein, cancer antigen 15-3, cancer antigen 19-9, migration inhibitory factor, carcinoembryonic antigen, cancer antigen 125, hepatocyte growth factor, soluble Fas, tumor necrosis factor-α, stem cell factor, and osteopontin. As most markers were also elevated in benign breast diseases, only cancer antigen 15-3 showed significant differences to cancer patients (p ≤ 0.001). The resulting areas under the curve in receiver operating characteristic curves for discrimination between benign and malignant breast diseases achieved 0.71 with a sensitivity of 33.8% at 95% specificity. Multiplexing enables parallel analysis of different biomarker classes for cancer detection. Established cancer antigen 15-3 proved to be most relevant for differential diagnosis.


Assuntos
Biomarcadores Tumorais/sangue , Neoplasias da Mama/sangue , Diagnóstico Diferencial , Mucina-1/sangue , Neoplasias/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Antígeno Ca-125/sangue , Antígeno CA-19-9/sangue , Antígeno Carcinoembrionário/sangue , Feminino , Humanos , Imunoensaio , Proteínas de Membrana/sangue , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Neoplasias/patologia , Osteopontina/sangue , Fator de Necrose Tumoral alfa/sangue , alfa-Fetoproteínas/biossíntese
15.
Anticancer Res ; 37(5): 2477-2486, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28476816

RESUMO

BACKGROUND/AIM: We evaluated the diagnostic performance of a newly-launched magnetic bead-based multiplex immunoassay panel including cancer, apoptotic, immunological and angiogenesis biomarkers for differential diagnosis of colorectal cancer (CRC). PATIENTS AND METHODS: Serum samples of 106 individuals comprising of 35 patients with CRC (23 colon cancer, 12 rectal cancer), 20 with respective benign colorectal diseases and 51 healthy controls were analyzed by the Milliplex™ MAP Human Circulating Cancer Biomarker Panel 1 run on the Bio-Plex™ 200 System. RESULTS: IL-8, CEA, HGF, TNFα, CYFRA 21-1, OPN, TGFα, CA 19-9, CA 125, AFP and sFas showed significantly higher levels in cancer samples compared to healthy controls. It is noteworthy that comparing CRC and benign colorectal disease samples, many immunological and cell death markers were elevated as well. Exclusively, six markers were distinguished significantly between both groups: CEA showed the best performance in differential diagnosis reaching an AUC of 0.859 in ROC curve followed by CA 19-9, CYFRA 21-1, IL-8, CA 125 and OPN reaching AUCs between 0.696 and 0.744. Correlation with tumor stage was found for CEA, sFas and CYFRA 21-1. Finally marker scores were assembled showing that a combination of CEA and CA 19-9 had a higher AUC (0.893) compared to the biomarkers alone. CONCLUSION: Differential diagnosis of CRC can be improved by new biomarker classes and their combination assessed by novel multiplex immunoassay.


Assuntos
Biomarcadores Tumorais/sangue , Doenças do Colo/sangue , Doenças Retais/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos de Neoplasias/sangue , Antígeno Ca-125/sangue , Antígeno CA-19-9/sangue , Antígeno Carcinoembrionário/sangue , Doenças do Colo/diagnóstico , Doenças do Colo/patologia , Diagnóstico Diferencial , Feminino , Humanos , Imunoensaio , Interleucina-8/sangue , Queratina-19/sangue , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Osteopontina/sangue , Doenças Retais/diagnóstico , Doenças Retais/patologia , Adulto Jovem
16.
Br J Cancer ; 116(8): 1037-1045, 2017 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-28278517

RESUMO

BACKGROUND: This meta-analysis evaluated whether pretherapy serum levels of carcinoembryonic antigen (CEA) and cytokeratin-19 fragments (CYFRA 21-1) are predictive of response to therapy in non-small cell lung cancer (NSCLC) and whether changes in these markers during vs pretherapy are indicative of response. METHODS: Original peer-reviewed studies enrolling adults with untreated advanced NSCLC were identified using PubMed. Two reviewers independently extracted data from eligible studies and assessed study heterogeneity and the risk of study bias. RESULTS: Fourteen studies were eligible; 11 had objective response as an end point and three evaluated clinical benefit (i.e., response and stable disease). Study bias was relatively low. Both markers showed comparable modest predictive value across studies, with baseline CYFRA 21-1 numerically better in predicting treatment benefit. A good performance in identifying objective response during treatment was seen (AUC 0.724 (95% CI 0.667-0.785) for CYFRA 21-1 and 0.728 (95% CI, 0.599-0.871) for CEA). A decline in CYFRA 21-1 levels during treatment was highly indicative for objective response (sensitivity 79.1% (95% CI 71.5-85.1)). CONCLUSIONS: Comprehensive analysis of study heterogeneity and bias provides a high level of evidence for the clinical utility of CEA and CYFRA 21-1 for the prediction and monitoring of response in NSCLC.


Assuntos
Antígenos de Neoplasias/metabolismo , Biomarcadores Tumorais/metabolismo , Antígeno Carcinoembrionário/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Queratina-19/metabolismo , Neoplasias Pulmonares/patologia , Adulto , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/terapia , Terapia Combinada , Humanos , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/terapia , Prognóstico
17.
Biotechnol Bioeng ; 114(7): 1539-1549, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28092110

RESUMO

A biosensor detecting estrogens, progestogens, and androgens in complex samples and in a single step is described. Three Arxula adeninivorans yeast strains were created, each strain producing a different recombinant human hormone receptor and a different fluorescent reporter protein. These strains were then mixed to create G1212/YRC102-hHR-fluo, the biological component of the biosensor. During incubation with G1212/YRC102-hHR-fluo, hormones present in a sample bind to their target receptor, which leads to the production of a specific fluorescent protein. Three fluorescence scans of the yeast suspension determine which fluorescence protein has been produced, thus revealing which hormone receptor (estrogen, progesterone, and androgen) has been activated by the hormones or hormone mimics present in the sample. The biosensor has similar sensitivities to the existing A. adeninivorans cell-based assays. The detection of the three hormone classes in one single experiment reduces the labor and time required to assay for the three hormone classes. The biosensor was also trialed with animal serum samples for the detection of progestogens, androgens, and estrogens and gave results that correlated well with ELISA analysis in case of progestogens. These results highlight the potential usefulness of the biosensor for comprehensive determination of hormone status in samples from veterinary origin. Biotechnol. Bioeng. 2017;114: 1539-1549. © 2017 Wiley Periodicals, Inc.


Assuntos
Ascomicetos/classificação , Ascomicetos/efeitos dos fármacos , Bioensaio/instrumentação , Técnicas Biossensoriais/instrumentação , Hormônios Esteroides Gonadais/sangue , Hormônios Esteroides Gonadais/farmacologia , Animais , Callithrix , Desenho de Equipamento , Análise de Falha de Equipamento , Hormônios Esteroides Gonadais/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Especificidade da Espécie , Espectrometria de Fluorescência/instrumentação
18.
Phytochemistry ; 124: 46-57, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26833384

RESUMO

In Brassica napus, suppression of the key biosynthetic enzyme UDP-glucose:sinapic acid glucosyltransferase (UGT84A9) inhibits the biosynthesis of sinapine (sinapoylcholine), the major phenolic component of seeds. Based on the accumulation kinetics of a total of 158 compounds (110 secondary and 48 primary metabolites), we investigated how suppression of the major sink pathway of sinapic acid impacts the metabolome of developing seeds and seedlings. In UGT84A9-suppressing (UGT84A9i) lines massive alterations became evident in late stages of seed development affecting the accumulation levels of 58 secondary and 7 primary metabolites. UGT84A9i seeds were characterized by decreased amounts of various hydroxycinnamic acid (HCA) esters, and increased formation of sinapic and syringic acid glycosides. This indicates glycosylation and ß-oxidation as metabolic detoxification strategies to bypass intracellular accumulation of sinapic acid. In addition, a net loss of sinapic acid upon UGT84A9 suppression may point to a feedback regulation of HCA biosynthesis. Surprisingly, suppression of UGT84A9 under control of the seed-specific NAPINC promoter was maintained in cotyledons during the first two weeks of seedling development and associated with a reduced and delayed transformation of sinapine into sinapoylmalate. The lack of sinapoylmalate did not interfere with plant fitness under UV-B stress. Increased UV-B radiation triggered the accumulation of quercetin conjugates whereas the sinapoylmalate level was not affected.


Assuntos
Brassica napus , Glucosiltransferases/metabolismo , Brassica napus/enzimologia , Brassica napus/genética , Brassica napus/metabolismo , Brassica napus/efeitos da radiação , Colina/análogos & derivados , Colina/metabolismo , Colina/efeitos da radiação , Cotilédone/metabolismo , Ácidos Cumáricos/análise , Ácidos Cumáricos/metabolismo , Ácidos Cumáricos/efeitos da radiação , Glucosiltransferases/efeitos da radiação , Malatos/metabolismo , Estrutura Molecular , Fenilpropionatos/metabolismo , Plântula/metabolismo , Sementes/metabolismo , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...